← Inbox

C3D-0639 · Read storm labels + pipes (read-only) [C3D-RDSTM] done

Dump V-STORM-* text and pipe lengths to compare with the redline worksheet.

Script file
C3D-0639.cs
Target
261004-C-Store As-Built Storm.dwg · model space
Author
claude
Approved
yes · auto-auth
Timeout
60s

C# payload

var ms=(BlockTableRecord)Tx.GetObject(SymbolUtilityServices.GetBlockModelSpaceId(Db),OpenMode.ForRead);
foreach(ObjectId id in ms){ var e=Tx.GetObject(id,OpenMode.ForRead) as Autodesk.AutoCAD.DatabaseServices.Entity; if(e==null||!e.Layer.StartsWith("V-STORM")) continue;
 if(e is MText){ var m=(MText)e; Log(e.Layer+" MT h="+e.Handle+" @"+m.Location.X.ToString("F1")+","+m.Location.Y.ToString("F1")+" : "+m.Text.Replace(((char)10).ToString()," / ").Replace(((char)13).ToString(),"")); }
 else if(e is DBText){ var t=(DBText)e; Log(e.Layer+" TX h="+e.Handle+" : "+t.TextString); }
 else if(e is Line){ var l=(Line)e; double d=Math.Sqrt(Math.Pow(l.EndPoint.X-l.StartPoint.X,2)+Math.Pow(l.EndPoint.Y-l.StartPoint.Y,2)); Log(e.Layer+" LINE h="+e.Handle+" len2d="+d.ToString("F2")+" "+l.StartPoint.X.ToString("F1")+","+l.StartPoint.Y.ToString("F1")+" -> "+l.EndPoint.X.ToString("F1")+","+l.EndPoint.Y.ToString("F1")); }
 else if(e is Polyline){ var p=(Polyline)e; Log(e.Layer+" PL h="+e.Handle+" len="+p.Length.ToString("F2")); }
 else Log(e.Layer+" "+e.GetType().Name+" h="+e.Handle);
}

Result

Status
success
Drawing file
C:\Users\sanja\OneDrive\_SurveyDisco\261004 - 5030 E Lake Pkwy, Stockbridge, GA 30281, USA\261004-C-Store As-Built Storm.dwg
Message
Executed C3D-0639 (0 entities touched).
Entities
—
Duration
1053 ms
Civil 3D
25.0.0.0

Log

V-STORM-TEXT MT h=307D9 @2296604.6,1280217.9 : DI A4 / RIM 729.21 / INV 725.48 / 18" CONC
V-STORM-TEXT MT h=307DA @2296601.7,1280155.6 : DI A3 / RIM 728.30 / INV 724.35 / 18" METAL
V-STORM-TEXT MT h=307DB @2296580.1,1280056.7 : DI A2 / RIM 727.60 / INV 722.87 / 18" CONC
V-STORM-TEXT MT h=307DC @2296551.9,1279965.9 : DI-RISER A1 / RIM 727.31 / INV 717.20 / 2' ROUND
V-STORM-TEXT MT h=307DD @2296752.6,1280176.8 : DI B4 / RIM 727.51 / INV 724.11 / 18"
V-STORM-TEXT MT h=307DE @2296713.7,1280084.7 : DI B3 / RIM 727.53 / INV 722.45 / 18" CONC
V-STORM-TEXT MT h=307DF @2296695.9,1280006.4 : DI B2 / RIM 726.61 / INV 720.51 / 18" CONC
V-STORM-TEXT MT h=307E0 @2296624.9,1280028.3 : DI-RISER B1 / RIM 727.67 / INV 724.90 (6" HDPE) / INV 722.37 (24" CMP) / BOT 716.57 (18" CONC)
V-STORM-TEXT MT h=307E1 @2296659.3,1279984.9 : C3 / RIM 726.78 / INV 716.71
V-STORM-PIPE LINE h=30826 len2d=33.34 2296577.5,1280209.6 -> 2296576.9,1280176.3
V-STORM-PIPE LINE h=30827 len2d=122.60 2296576.9,1280176.3 -> 2296577.1,1280053.7
V-STORM-PIPE LINE h=30828 len2d=83.87 2296577.1,1280053.7 -> 2296586.2,1279970.3
V-STORM-PIPE LINE h=30829 len2d=92.41 2296749.6,1280173.8 -> 2296741.7,1280081.8
V-STORM-PIPE LINE h=3082A len2d=89.95 2296741.7,1280081.8 -> 2296681.2,1280015.2
V-STORM-PIPE LINE h=3082B len2d=62.99 2296681.2,1280015.2 -> 2296618.4,1280009.7
V-STORM-TEXT MT h=3082E @2296574.2,1280193.0 : 33.34' - 18" ALTyp2
V-STORM-TEXT MT h=3082F @2296580.2,1280192.9 : 3.39%
V-STORM-TEXT MT h=30830 @2296580.0,1280115.0 : 122.60' - 18" ALTyp2
V-STORM-TEXT MT h=30831 @2296574.0,1280115.0 : 1.21%
V-STORM-TEXT MT h=30832 @2296584.6,1280012.4 : 83.87' - 18" ALTyp2
V-STORM-TEXT MT h=30833 @2296742.7,1280128.0 : 92.41' - 18" RCP
V-STORM-TEXT MT h=30834 @2296748.7,1280127.5 : 1.80%
V-STORM-TEXT MT h=30835 @2296709.2,1280050.5 : 89.95' - 18" RCP
V-STORM-TEXT MT h=30836 @2296713.7,1280046.5 : 2.16%
V-STORM-TEXT MT h=30837 @2296649.5,1280015.5 : 62.99' - 18" RCP
V-STORM-TEXT MT h=30838 @2296650.1,1280009.5 : -2.95%
V-STORM-PIPE LINE h=4AF47 len2d=18.46 2296601.2,1280016.3 -> 2296618.4,1280009.7
V-STORM-HW PL h=4AF69 len=20.25
V-STORM-PIPE LINE h=4AF6A len2d=58.40 2296712.1,1279958.3 -> 2296757.7,1279921.9
V-STORM-HW LINE h=4AF7A len2d=5.53 2296703.8,1279959.1 -> 2296709.2,1279957.7
V-STORM-HW Arc h=4AF7B
V-STORM-HW LINE h=4AF7C len2d=4.62 2296711.5,1279961.2 -> 2296708.7,1279964.9
V-STORM-HW LINE h=4AF7D len2d=1.03 2296708.7,1279964.9 -> 2296708.2,1279965.8
V-STORM-PIPE MT h=4AFF2 @2296219.8,1279910.2 : UNDERGROUND DETENTION PER DEV3896 SHEET C7.0: 8 ROWS 60" CMP x 160' @ 0.5%, INV 714.50 / CROWN 720.50 (PLAN). LOCATION ROTATED TO FIELD-LOCATED DI-RISER A1; DI-RISER B1 AND MH C3 FALL AT HEADER CORNERS. EXTENTS, BARREL COUNT AND INVERTS NOT FIELD VERIFIED. RISER BOTTOMS MEASURED TO SILT: A1 717.20, B1 716.57, C3 716.71.OUTLET CONTROL STRUCTURE (OCS C3), CDS4030-8-C (JB C2) AND 36" RCP (STM C1) SHOWN ON SHEET C7.0 WERE NOT FOUND. MH AT C3 LOCATION IS A 36" FRAME OVER THE DETENTION HEADER, INTERIOR SILTED, NO OUTLET PIPE VISIBLE. DETENTION OUTLET NOT DETERMINED.CONC PIPE UNDER WOLF CREEK DR (TOP 716.02 / INV 712.32) NOT CONNECTED TO ANY LOCATED STRUCTURE. FLUME (717.11) AND HEADWALL (719.90) CARRY SURFACE RUNOFF UNDER ROAD.

Notes

What worked, what didn't, job-specific gotchas — flagged notes feed the recipes.

No notes yet.